TL-1600SI

Product Features BRIGHT II control system can automatically compensate the value of control parameters according to the change of environment; Programmable multi-segment parameter setting: 30 segments 99 cycles design; The controller can store data records for more than 10 years (not stored by SD card), and record equipment events with exact time, and export them by U disk in unchangeable file format for viewing and backup, and trace the data; The administrator can assign 14 kinds of equipment operation permissions to 5 operators; Support data and curve online viewing; The circulating air volume can be adjusted manually according to the…

Description

Product Features

BRIGHT II control system can automatically compensate the value of control parameters according to the change of environment;

Programmable multi-segment parameter setting: 30 segments 99 cycles design;

The controller can store data records for more than 10 years (not stored by SD card), and record equipment events with exact time, and export them by U disk in unchangeable file format for viewing and backup, and trace the data;

The administrator can assign 14 kinds of equipment operation permissions to 5 operators;

Support data and curve online viewing;

The circulating air volume can be adjusted manually according to the sample loading condition;

Rapid recovery of temperature and humidity after opening the door;

Protection function: upper and lower limit over temperature alarm, over temperature shutdown protection, door open alarm, water shortage alarm, sensor fault alarm, overload protection, leakage protection, compressor over temperature protection;

Glass observation inner door design;

Equipped with mechanical lock, prevents from opening at will;

Equipped with printer;

Imported illumination sensor, real-time monitoring and accumulation of the actual illumination received value;

Illumination module shelf, illuminance is stepless adjustable, when the total illumination value is reached, the LED lamp will be turned off automatically;

Illumination value is displayed in real-time and can be printed;

Meet the test requirement of total illuminance not less than 1.2×106Lux·hr.

Technical Parameters

Volume [L]: 1600

Temp. Range without Humidification and without Illumination [°C]: 0~85

Temp. Range without Humidification and with Illumination [°C]: 10~85

Temp. Range with Humidification and without Illumination [°C]: 10~60

Temp. Range with Humidification and with Illumination [°C]: 15~60

Temp. Resolution [°C]: 0.1

Temp. Fluctuation at 25°C [°C]: ±0.5

Temp. Uniformity at 25°C [°C]: ±2

Humidity Range [%]: 20~98

Humidity Fluctuation [%]: ±5

Illuminance [Lux]: 0~10000

Illuminance Deviation [Lux]: ±500

Power [W]: 3650

Timer Range per Segment [h]: 1~9999

Internal Dimensions W×D×H [mm]: 1400×850×1350

Housing Dimensions W×D×H [mm]: 1562×1220×2040

Number of Shelves (std./max.) [pc]: 4 / 12

Number of Illumination Module Shelves [pc]: 1

Number of Illumination Source Shelves [pc]: 1

Maximum Number of Illumination Shelves [pc]: 4

Door Type / Number of Shelves per Layer [pc]: Side-by-side / 1